1
Hi, Guest!

  LOKASI :  Jakarta Utara

  AKTIVITAS :  Yesterday

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !
CV. KARYA MANDIRI VALVE TELP/FAX : +6221-22065357 E-MAIL : CV.KMV2@GMAIL.COM MOBILE & W.A : 0852 8804 0822

CONTROLLER 4150/4160 K

Update Terakhir
:
25 / 06 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
Supplier & Stockist Valve, Flanges, Pipe & Fittings.

Valve : Ball Valve, Check Valve, Gate Valve, Pressure Reducing Valve, Safety Valve, Globe Valve, Butterfly Valve.

Flanges : WN Flange, Blind Flange , Slip On Flange, Jis / PN STD/ N/S

Fittings & Forged Fittings : Elbow, Tee, Cap, Redducer.

Material : CS, SS, PVC, Kuningan, C.I, D.I.

Detail CONTROLLER 4150/4160 K

Specifications
Available Configurations (See table 1)
Input Signal(1)
Type: _ Gauge pressure, _ vacuum,_ compound pressure, or _ differential pressure of a liquid or gas
Output Signal(1)
Proportional or Proportional-Plus-Reset
Controllers and Transmitters: _ 0.2 to 1.0 bar (3 to 15 psig) or _ 0.4 to 2.0 bar (6 to 30 psig)
pneumatic pressure signal
Differential Gap Controllers: _ 0 and 1.4 bar (0 and 20 psig) or _ 0 and 2.4 bar (0 and 35 psig)
pneumatic pressure signal
Action: Control action is field reversible between direct (increasing sensed pressure produces
increasing output signal) and _ reverse (increasing sensed pressure produces decreasing
output signal). The suffix R is added to the type number of a construction specified for reverse
action.
Supply and Output Connections
1/4- inch NPT female
Proportional Band(1) Adjustment For Proportional and Proportional-Plus-Reset
Controllers:
0.2 to 1.0 bar (3 to 15 psig) Output: Full output pressure change adjustable from 3 to 100% of the
sensing element range.
0.4 to 2.0 bar (6 to 30 psig) Output: Full output pressure change adjustable from 6 to 100% of the
sensing element range.
Differential Gap Adjustment For Differential Gap Controllers: Full output pressure change adjustable from 15% to 100% of sensing element range
Reset(1) Adjustment For Proportional-Plus-Reset Controllers:
Adjustable from 0.01 to 74 minutes per repeat (100 to 0.01 repeats per minute)
Zero(1) Adjustment (Transmitters Only)
Continuously adjustable to position span of less than 100% anywhere within the sensing element range
Span(1) Adjustment (Transmitters Only)
Full output pressure change adjustable from 6 to 100% of process sensing element range
Performance Repeatability(1): 0.5% of sensing element range
Dead Band(1) (Except Differential Gap Controllers(2)): 0.1% of output span
Typical Frequency Response at 100% Proportional Band.
Output to Actuator: 0.7 Hz and 110 degree phase shift with 1850 cm3 (113 inches3) volume actuator
at mid-stroke
Output to Positioner Bellows: 9 Hz and 130 degree phase shift with 0.2 to 1.0 bar (3 to 15psig)
output to 33 cm3 ( 2 inches3 ) bellows
Ambient Operating Temperature Limits(3)
_ Standard Construction: 40 to 93_C (40 to 200_F)
_ 4160KF (w/Reset Relief): 40 to 71_C (40 to160_F)

Tampilkan Lebih Banyak
cv. karya mandiri valve
cv. karya mandiri valve

CV. KARYA MANDIRI VALVE

PREMIUM GOLD 3 Tahun
Jl. Pohon Beringin No.11 RT.07 RW.03 Sunter Jaya - Jakarta Utara, Jakarta Utara
Indonesia 14350
Jakarta Utara
20 / 09 / 2019
Hubungi Kami

Detail CONTROLLER 4150/4160 K

Specifications
Available Configurations (See table 1)
Input Signal(1)
Type: _ Gauge pressure, _ vacuum,_ compound pressure, or _ differential pressure of a liquid or gas
Output Signal(1)
Proportional or Proportional-Plus-Reset
Controllers and Transmitters: _ 0.2 to 1.0 bar (3 to 15 psig) or _ 0.4 to 2.0 bar (6 to 30 psig)
pneumatic pressure signal
Differential Gap Controllers: _ 0 and 1.4 bar (0 and 20 psig) or _ 0 and 2.4 bar (0 and 35 psig)
pneumatic pressure signal
Action: Control action is field reversible between direct (increasing sensed pressure produces
increasing output signal) and _ reverse (increasing sensed pressure produces decreasing
output signal). The suffix R is added to the type number of a construction specified for reverse
action.
Supply and Output Connections
1/4- inch NPT female
Proportional Band(1) Adjustment For Proportional and Proportional-Plus-Reset
Controllers:
0.2 to 1.0 bar (3 to 15 psig) Output: Full output pressure change adjustable from 3 to 100% of the
sensing element range.
0.4 to 2.0 bar (6 to 30 psig) Output: Full output pressure change adjustable from 6 to 100% of the
sensing element range.
Differential Gap Adjustment For Differential Gap Controllers: Full output pressure change adjustable from 15% to 100% of sensing element range
Reset(1) Adjustment For Proportional-Plus-Reset Controllers:
Adjustable from 0.01 to 74 minutes per repeat (100 to 0.01 repeats per minute)
Zero(1) Adjustment (Transmitters Only)
Continuously adjustable to position span of less than 100% anywhere within the sensing element range
Span(1) Adjustment (Transmitters Only)
Full output pressure change adjustable from 6 to 100% of process sensing element range
Performance Repeatability(1): 0.5% of sensing element range
Dead Band(1) (Except Differential Gap Controllers(2)): 0.1% of output span
Typical Frequency Response at 100% Proportional Band.
Output to Actuator: 0.7 Hz and 110 degree phase shift with 1850 cm3 (113 inches3) volume actuator
at mid-stroke
Output to Positioner Bellows: 9 Hz and 130 degree phase shift with 0.2 to 1.0 bar (3 to 15psig)
output to 33 cm3 ( 2 inches3 ) bellows
Ambient Operating Temperature Limits(3)
_ Standard Construction: 40 to 93_C (40 to 200_F)
_ 4160KF (w/Reset Relief): 40 to 71_C (40 to160_F)

Tampilkan Lebih Banyak