📞 +62 21 8888 1234 📧 cv.km2@gmail.com 📍 Jakarta, Indonesia
|
Logo Karya Mandiri Valve
KARYA MANDIRI VALVE
Quality Valve Solutions for a Better Tomorrow
Home About Us
Contact
Home/ Products/ Control & Safety/ Pressure Reducing Valve
Control & Safety

Pressure Reducing Valve

Direct Acting, Pilot Operated, Piston & Diaphragm Type

Pressure Reducing Valve (PRV) is an automatic pressure regulating valve that functions to lower the variable inlet pressure into a constant outlet pressure according to the set point. This valve is crucial to protect downstream equipment from excessive pressure and maintain piping system stability.

Download Catalog
Pressure Reducing Valve

Product Description

Pressure Reducing Valve (PRV) operates by automatically adjusting the disc opening based on the outlet pressure sensor. If the outlet pressure drops below the set point, the spring or pilot will open the disc wider to increase flow. Conversely, if the outlet pressure rises above the set point, the disc will close partially to reduce flow.

This precision control mechanism ensures that downstream equipment such as pumps, heat exchangers, or household taps receive safe and consistent pressure, even if the inlet pressure from the main pump or boiler fluctuates.

Karya Mandiri Valve provides PRVs for various media (Water, Steam, Gas, Oil) with Direct Acting, Pilot Operated, Piston, and Diaphragm types. Available in Cast Iron, Bronze, Stainless Steel, and Carbon Steel materials according to ASME and BS standards.

Applications

  • Clean Water Distribution (PDAM/Commercial Building)
  • Steam & Boiler Systems (Low pressure to process)
  • Compressed Air Systems
  • Industrial Gas (Oxygen, Nitrogen, LPG)
  • HVAC & Chilled Water Systems
  • Fire Protection / Hydrant Systems
  • Palm Oil Mills & Petrochemicals

Quick Specs

Size
½" – 16" (DN15 – DN400)
Inlet Pressure
Maks. 250 bar
Outlet Pressure
0.5 – 50 bar (Adjustable)
Material
CI, DI, CS, SS316, Bronze
Connection
Flanged, Threaded, SW
Standard
ASME B16.34, BS EN 1567

Product Gallery

Select a tab to view details of types and pressure classes.

Direct Acting PRV
Type

Direct Acting PRV

Outlet pressure directly opposes the spring force. Simple design, lightweight, and economical. Suitable for low to medium flow rates with slight pressure fluctuations (water line, air compressor).

CompactSimple Design
Pilot Operated PRV
Type

Pilot Operated PRV

Uses a small pilot valve to control the main diaphragm. Provides high precision control, large flow capacity, and excellent outlet pressure stability even when flow changes.

High CapacityHigh Precision
Piston Type PRV
Type

Piston Type PRV

Uses a metal piston as the main driver. Resistant to higher pressures and temperatures compared to rubber diaphragms. Often used for steam and hot vapors.

High Temp / SteamDurable
Diaphragm Type PRV
Type

Diaphragm Type PRV

Uses a flexible diaphragm (rubber/PTFE) that is very sensitive to pressure changes. Provides fast response and is suitable for corrosive liquids or clean water.

Sensitive ResponseWater/Chemical
Pressure Reducing Check Valve
Type

Pressure Reducing Check Valve

Combination of Pressure Reducing Valve and Check Valve. Reduces pressure while preventing backflow. Saves installation space because it doesn't require 2 separate valves.

Dual FunctionSpace Saving
Balanced Bellows PRV
Type

Balanced Bellows PRV

Equipped with bellows that balance the force from inlet pressure, so the outlet pressure remains precise even if the inlet pressure varies significantly. Suitable for gas and steam.

Variable InletHigh Accuracy
ASME

ASME Class (Inlet Flanged)

— Standard ASME B16.5 / B16.34
150#
Class 150
≈ 19 bar
285 psi
300#
Class 300
≈ 51 bar
740 psi
600#
Class 600
≈ 102 bar
1480 psi
900#
Class 900
≈ 153 bar
2220 psi
1500#
Class 1500
≈ 255 bar
3705 psi
2500#
Class 2500
≈ 425 bar
6170 psi
PN

PN — Nominal Pressure (DIN / EN)

— Standard EN 1092
PN 10
Low Pressure
10 bar
145 psi
PN 16
Low Pressure
16 bar
232 psi
PN 25
Medium Pressure
25 bar
363 psi
PN 40
Medium Pressure
40 bar
580 psi
PN 63
High Pressure
63 bar
914 psi
PN 100
High Pressure
100 bar
1450 psi
📊

Note for PRV: The class values above refer to the maximum inlet pressure rating held by the valve body. Outlet Pressure is adjusted via spring or pilot under the inlet rating (e.g., Class 300# inlet PRV can be set outlet at 5 bar, 10 bar, up to 40 bar). Spring range selection must be adjusted to the desired outlet pressure.

Technical Specifications

SpecificationDetail
TypeDirect Acting, Pilot Operated, Piston Type, Diaphragm Type, Balanced Bellows, PRCV (Reducing Check)
Inlet Size½" s/d 16" (DN15 s/d DN400)
Pressure Class (Inlet)ASME 150# – 2500#, PN 10 – PN 100, Threaded (NPT/BSP), Socket Weld
Outlet Pressure Range0.5 bar s/d 50 bar (Adjustable, tergantung spring range)
Body MaterialCast Iron (FC25), Ductile Iron (FCD450), Carbon Steel (WCB/A216), Stainless Steel (CF8M/A351), Bronze (C84400)
Trim & Elastomer MaterialSS304, SS316, NBR, EPDM, Viton, PTFE (Diaphragm/Seat)
Fluid ServiceAir, Steam (Uap), Gas, Compressed Air, Thermal Oil, Corrosive Liquids
Standard & CodeASME B16.34, BS EN 1567 (Water), ASME Sec. VIII, IEC 60534
CertificateMaterial Test Certificate (EN 10204 3.1), WRAS (Untuk Drinking Water), CE Marking

Need a Pressure Reducing Valve Quotation?

Contact our sales team. Send your specifications (Inlet Pressure, Outlet Pressure, Flow Rate, Fluid) and we will provide the best offer within 24 hours.

Download Catalog
Select Sales Admin
Select Contact to send request
💡 Select available admin